BACKGROUND: Sinusoidal lower body negative pressure (SLBNP) has been used to investigate the cardiovascular response to slow periodic changes in blood shifts, but measurements of slow fluctuations take a long time if measured for each period of SLBNP separately. Our study aimed
to investigate whether the cardiovascular responses to superimposed SLBNP (S-SLBNP), which is expected to reduce the measurement time, are different from responses measured individually.METHODS: S-SLBNP was configured by superimposing two conventional SLBNPs (C-SLBNP) at 180-s and
30-s periods in the pressure range from 0 to −25 mmHg. As the S-SLBNP has double the static load of C-SLBNP, we also used offset SLBNP (O-SLBNP), which has the same static load level as S-SLBNP. Heart rate (HR), thoracic impedance (Z0), and mean arterial pressure (MAP) were
measured from 11 male subjects. The transfer functions of gains from MAP to HR (Gain-HR/MAP) and from Z0 to HR (Gain-HR/Z0) were calculated as indexes of arterial baroreflex and cardiopulmonary baroreflex regulation of HR, respectively.RESULTS: The Gain-HR/MAP
in the 180-s period (2.11 ± 0.17 bpm/mmHg; mean ± SEM) was larger than that of the 30-s period (1.04 ± 0.09 bpm/mmHg); however, there was no significant difference between the SLBNP conditions. The Gain-HR/Z0 in C-SLBNP (9.37 ± 1.47 bpm/ohm) was smaller
than that of the other conditions [18.46 ± 2.45 bpm/ohm (O-SLBNP); 16.09 ± 2.29 bpm/ohm (S-SLBNP)].DISCUSSION: Using S-SLBNP could reduce the measurement time needed to examine the arterial baroreflex. However, the cardiopulmonary baroreflex was modified by the static
load of SLBNP.Ishibashi K, Oyama F, Yoshida H, Iwanaga K. Additive effects of sinusoidal lower body negative pressure on cardiovascular responses. Aerosp Med Hum Perform. 2017; 88(2):137–141.